Advantage : Fast & Easy
Installation
Service : For all
types of liquids (without Moisture, Fumes and
Foam)
Working principle : Capacitance
This instrument works on principle
of change in Capacitance between two
metallic surfaces.
The Sensing Probe would be SS rod
coated with PTFE and the Metallic
Tank would be considered as Reference.
If the tank is non metallic a separate
metallic rod (To be mounted parallel
to the Sensing Probe, and not touching
to Sensor Probe) would be required
to be used as Reference Rod.
Accuracy : 1% FSD
Mounting : from Top of
the tank
Level Indication : Digital through
a Panel mounted Indicator (needs
external power supply)
Max.sensing
length of the transmitter : 3 meters
Sensor MOC : PFTE coated
SS 316 (Rod or, Rope)
Process
connection: Threaded, flanged or, Triclover
connection
Electrical
Terminal Housing : Weather proof Aluminium or,
flameproof
Output of the transmitter : 4 to 20 mA
Power Supply : 24 V DC
(2 wire)
Max. Fluid Temp. :
up to 150 degree C
Max. Fluid
Pressure : 10 Kg/cm2
Application : For liquid
level indication in Digital form and
their controls.
If temperature is continuously varying,
capacitance level indicators are not
recommended.
|