Range 0 to 2 mm Wc up to 0 to
2500 mm Wc
Accuracy
: +/- 1% FS
Temperature Range : -10 to 80 Degree C (for
high temperature use of impulse tube is
advisable)
Migration
: Impossible
No. of
Switches : one no.
Type of
Switches : Micro Switches - SPDT
1 A 230 V
AC or, 2 A 250 V AC, 5 A 250 V AC
Housing IP 54 or IP 65
Pressure
Housing Plastic, MS, Aluminium or, SS 316
Sensing
Diaphragm : Nitrile, Teflon or Neoprene
Process
Connection hose fitting or, ¼” BSP (F)
Application : For Filter, Heat exchanger
healthiness indication & auto cleaning
systems. Air,